Saleae Support
HomeDownloadUser ForumContact Us
  • Saleae Support
  • Orders & Shipping
    • Place an Online Order
    • Place a Purchase Order (PO)
    • Get a Quote
    • Check your Order Status
    • Distributors
    • Pricing and Availability
    • Discounts
    • Tax & VAT Exemption
    • Saleae Business Information
    • Shipping Policy
    • Receiving Invoices
    • Sales FAQ
      • What Is Included with the Product?
      • What Accessories Should I Purchase with My Device?
      • Is the Saleae Software Sold Separately?
      • Does Saleae Have a Trade-In or Upgrade Plan?
      • How Can I Find the Current Status of My Order?
      • Part Numbers, ECCN, HS Codes, and Country of Origin
      • Discontinued Products
      • International Customs and Duty Information
      • Does Saleae Offer Demo Units or Units on Loan?
      • When Is My Card Charged?
      • Unable to Ship to PO Box Error
      • Referred a Friend? Email Us!
      • Does Saleae Provide Drop-Shipping Service?
  • Getting Started
    • Setup
    • Configure
    • Record
    • Navigate
    • Measure
    • Trigger
    • Protocols
  • User Guide
    • Product Summary
    • Safety & Warranty
    • Supported Voltages
    • Device Calibration
    • Using Logic
      • Navigating the Software
      • Connecting the Logic Analyzer
      • Logic Accessories
      • Device Settings
      • Capture Modes
      • Navigating Your Data
      • Time Bar Settings
      • Measurements, Timing Markers & Notes
      • Capture & Preset File Management
      • Exporting Data
      • Delete Part of your Capture
      • Analyzers
      • Data Table & Terminal View
      • Color Themes
      • Demo Mode
      • Software Glitch Filter
      • Keyboard Shortcuts
      • Automatic Updates
      • Message Us Directly
  • Software
    • Supported Operating Systems
    • Download
    • Installation
    • Firmware Updates
    • Driver Install
    • Legacy Software
      • Logic 1.x Download (Deprecated)
      • Logic 1.x Installation (Deprecated)
      • Logic 1.x Changelog (Deprecated)
      • Logic 1.x User Guide (Deprecated)
  • Protocol Analyzers
    • Supported Protocols
    • Analyzer User Guides
      • Async Serial Analyzer - User Guide
        • Decode UART
        • Decode RS-232, RS-485, & RS-422
      • SPI Analyzer - User Guide
      • I2C Analyzer - User Guide
      • CAN Analyzer - User Guide
      • Simple Parallel Analyzer - User Guide
      • I2S / PCM Analyzer - User Guide
      • DMX-512 Analyzer - User Guide
      • SMBus Analyzer - User Guide
      • Decode Differential and High Voltage Data
  • Software Extensions
    • Extension Installation
    • Create and Use Extensions
    • High-Level Analyzer (HLA) Extensions
      • Shared High Level Analyzers (HLAs)
    • Measurement Extensions
      • Analog Measurement Extensions
      • Digital Measurement Extensions
    • Extension File Format
    • About Third-Party Extensions
    • Disabling Marketplace Extensions
    • Publish an Extension
    • HLA - Analyzer Frame Format
      • Async Serial - Frame Format
      • I2C - Frame Format
      • SPI - Frame Format
      • CAN - Frame Format
      • Manchester - Frame Format
      • 1-Wire - Frame Format
      • Async RGB LED - Frame Format
      • Simple Parallel - Frame Format
      • LIN - Frame Format
      • I2S - Frame Format
    • API Documentation
  • Automation & Analyzer SDK
    • Automation API - Logic 2
    • Automation API - Legacy Logic 1.x
    • Protocol Analyzer SDK
      • FrameV2 / HLA Support - Analyzer SDK
      • Rename a Custom Analyzer
    • More Information on our SDKs
      • Can I Access Raw Data in Real Time?
      • Migrate Code to the New Analyzer SDK
      • Sharing Custom Low-Level Analyzer (LLA) Code
      • VB.NET Support for Automation
  • Datasheets & Specifications
    • Datasheets
    • Logic Hardware Revisions
    • Logic Dimensions
    • Compliance Documents
  • Troubleshooting
    • Installation Errors
    • The Software Fails to Launch
    • The Software Crashes
    • Logic is Not Detected
    • Getting your Machine ID
    • Getting your Software Crash Logs
    • Getting the Console Output
    • Location of Your Config File
    • Error Message: ReadTimeout
    • The Captured Data Looks Incorrect
    • The Captured Data is Corrupted
    • A Protocol Analyzer Produces Unexpected Results
    • The 'Waiting for Trigger' Window Never Closes
    • Device USB VID and PID Information
    • Error Message: Out of Memory Exception Was Thrown
    • PC Performance Issues with Logic
    • Data Export Is Not Working
    • Error Message: A device was found, but the software was unable to access it
    • Trouble Downloading the Latest Software
    • Logic Does Not Connect over USB 3.0
    • Why Am I Seeing Spikes in the Digital Capture?
    • Logic Interferes with My Circuit Operation
    • The Add Analyzer Menu Is Not Displaying
    • Other Drivers Interfere with Logic's Operation
    • The Maximum Sample Rate is Not Selectable
    • The Digital and Analog Recording on the Same Channel Appear Different
    • Advanced USB Debugging for USB 3.0 Users with Linux Kernels 3.3 and Older
    • Saving or Loading Anything Crashes the Software
    • Error Message: The application was unable to start correctly (0xc0000005)
    • Memory Usage with Triggered Captures
    • The Cabinet File disk1.cab has an Invalid Digital Signature (Logic 1.x)
    • Software Crashes with Virtual Desktops
    • Pre-Trigger Buffer is Incomplete
    • Linux Shared Memory Crash
    • Missing Files: api-ms-win-crt-runtime-l1-1-0.dll or msvcp140.dll
    • Known Issues on OS X
    • A Measurement Appears Incorrect
    • All Known Issues
    • USB 3.0 Cable Customer Notice (2017)
    • Warning Message: Logic Pro is running as a USB 2.0 device
    • Software Issues with Encryption Products
    • Linux Permission Requirements for Logic Software
    • My Rise Time and Fall Time Measurements Seem Incorrect
    • The Analog Waveform Loads Very Slowly after Capture Is Complete
    • Input Channels are Missing
    • Exported MATLAB File Does Not Open
    • Saleae Logic LED Blinks Red
    • Crashes Caused by macOS Mojave (10.14)
    • Troubleshooting Signal Crosstalk
    • Error Message: DeviceSetupFailure
    • Error Message: Unable to detect WebGL and Other GPU Issues
    • Warning Message: Unsupported Version
    • Error Function: Device2::SetupDevice
    • Warning Message: Possible USB Host Controller Problem Detected
    • Error Message: StartCommandError
    • Logic 2 Error Messages
    • PC Detection Test
    • CentOS Compatibility Issues
    • Error Message: Failed to Load Extension
    • CSV Export is Slow
    • Set an Analyzer Starting Point in your Capture
    • Logic 2 is Consuming Disk Space
    • Connection Conflicts with USB Debuggers
    • PC Restart Causes Logic to Disconnect
    • HLA Fails to Display Special Characters
    • Data Table Shows Incorrect Values
    • Error Message: Failed to Load Custom Analyzer
    • Error Message: Capture Stopped
    • Error Loading Marketplace Extensions
    • Error: Capture stopped because backlog data exceeded 90%
    • This Analyzer's Native Export is Not Supported in Logic 2
    • Mouse Scrolling Issues
    • Error: A device was found, but it was removed before initialization completed
    • Error: An unknown error occurred during device connection
    • Visual Studio Error: Failed to Launch Debug Adapter
    • VS Code Fails to Launch Python Automation API Script
    • Analog Waveforms Do Not Appear on Linux
    • Reinstall USB Host Controller Drivers
  • FAQ
    • Technical FAQ
      • System Requirements for Saleae Products
      • What Is the Normal Behavior of the LED?
      • What Is the Difference between Logic/Logic16 (Gen1) and Logic 8/Pro 8/Pro 16 (Gen2)?
      • Recommended USB 3.0 Host Controller Cards
      • Device Settings Configuration Tips
      • What Is the Worst Case Channel to Channel Skew?
      • What is Asynchronous Sampling?
      • Which Saleae Products Can Decode 4-Bit Parallel LCD Communications?
      • How Can I Compare Two Clock Signals for Synchronization and Drift?
      • Converting I2S/PCM Captures into Audio
      • My Capture Shows an Uneven Duty Cycle
      • Can I Create or Edit .logicdata Files?
      • Can Saleae Logic Run on ARM / Apple Processors?
      • What Annotations Are Supported?
      • Time & Memory Saving Tools
      • How Can I Record Power Consumption?
      • Moving Logic to Its Own Host Controller
      • How Long Does It Take to Save a File?
      • XMonad on Linux Causes Issues
      • What Is the Maximum Bandwidth of Logic?
      • How Long Can I Record Data?
      • Can I Export Protocol Results Between Timing Markers?
      • Can I Generate an Analog Graph from Digital Data?
      • Time Measurement Error
      • Can These Products Replace an Oscilloscope?
      • Can I Use Multiple Logics on a Single PC?
      • Native Windowing Features Are Not Working Such as Snap or Gestures
      • Opening .logicdata Capture Files
      • How to Choose the Right Logic Analyzer for You
      • Saleae Open Source Support
      • How to Trigger the End of a Capture Instead of the Start
      • Using the Hardware with USB Extension Cables, Through Virtual Machines, or Ethernet Extenders
      • Are the Ground Pins Required for Each Input Used?
      • Can Saleae Products Output Data?
      • Resolution of the Analog Inputs
      • What Sampling Rate Should I Use?
      • Can I Share Data Captures with Others?
      • Binary Export Format (Digital) - Logic 1.x
      • MATLAB Data Export Format - Legacy Logic 1.x
      • Recording Multiple Protocols at the Same Time
      • Changing the Display Radix (Base)
      • Which Logic Analyzer Should I Get?
      • How to View and Debug Firmware Variables, State, and Function Calls
      • Using Saleae Logic Devices with Third-Party Pattern Generators
      • Can Logic Operate with a Full-Speed USB Isolator?
      • Which Saleae Devices Support Analog Recording?
      • How to Manage Protocol Analyzers when Using the Socket API
      • How to Export Serial Protocol Results to a Raw Binary File
      • How to Trigger On a Pulse with No Maximum Time Limit - Logic 1.x
      • Finding Your USB 3.0 Host Controller Information
      • Logic Reports Different USB Current Requirements
      • Is It Possible to Adjust the Logic Thresholds for the Digital Inputs?
      • Why Does Channel 0 Use a Black Wire?
      • Software Shows Multiple Logic Analyzers Attached
      • Are the Input Channels Isolated from Each Other?
      • Are There Feature Differences in the Software when Different Logic Analyzers Are Used?
      • Packet Level Decoding Support in the Analyzer SDK
      • What Higher-Level Protocol Analysis Features Are Available?
      • Support for USB 3.0 and USB 3.1
      • How Can I Compare Signals from Different Captures?
      • Do the Saleae Logic Analyzers Support Trigger Out?
      • Why is the Length of my Capture Incorrect?
      • The Options Button is Missing
      • Can I Change the Voltage Range of the Analog Inputs?
      • How Does the ASCII Radix Display Characters?
      • Do I Have a USB 3.0 Port?
      • What Is the Best Way to Compare Similar Sequences of Protocol Data?
      • Which Version of the Software Should I Use?
      • Import Custom Low Level Analyzer
      • OSX Analyzer SDK Xcode Setup
      • Can Custom Analyzers Process Analog Channels?
      • Automating Long Overnight Captures
      • What Options Are There to Export Multiple Protocol Analyzer Results into the Same File?
      • Do the Saleae Devices Support AC Coupling?
      • Suggestions for Capturing Multiple Instances of a Triggered Event Automatically
      • How Many Protocol Analyzers Can Be Used at Once?
      • Is It Possible to Run the Saleae Software on a PC without SSE2 Instructions?
      • Is It Possible to Import Data into the Logic Software?
      • How Do I Convert Exported CSV Analog Data in Voltages?
      • Is There Cross-Platform Support for the SaleaeSocketApi C# Project
      • Why Does Logic Get Warm?
      • Binary Export Format (Analog) - Logic 1.x
      • Electrical Isolation Suggestions
      • FCC and CE Testing Recommendations
      • 'Save Capture' and 'Export Data' is Disabled in the Software
      • File Format Description for Exporting Protocol Analyzer Results
      • Is There a Newer Version of the Software Available?
      • Is There a Way to Change the Window Resolution?
      • How Can I Extract Recorded Data Using Socket API?
      • Does the Software Support Windows 10 Tablets or Windows RT Tablets?
      • Standalone Software Information
      • Does the Saleae Software Support the Original Logic and Logic 16?
      • Timing Markers Disappear When I Start a New Capture
      • What Sample Rate Settings Are Available? Can I Sample at a Slower Rate?
      • How Do I Differentiate Data in the Export File when Duplicate Analyzers Are Used?
      • Running Multiple Versions of the Software
      • Test Clip Differences - Gen 1 & Gen 2
      • USB-C Cable Recommendations
      • Is My Capture Data Private?
      • Ethernet Connectivity Suggestions
      • Binary Export Format - Logic 2
      • Viewing I2C Addresses as 8-bit
      • Can I use Python Packages in my Custom Extension?
      • Are the Inputs Synchronously Sampled or Sweep Sampled?
      • Is Logic Affected by the Log4j Exploit?
      • Connecting Remotely with SSH
      • Is Silent Installation Supported?
      • Is the .sal File Format Documented?
      • Export Data via Socket API
      • Running Logic in a CI Environment on Windows with the SYSTEM Account
    • General FAQ
      • How Do I Get More Help on an Issue That's Outside the Scope of Saleae Support?
      • How to Identify Each Saleae Device
      • License for the Saleae Logic Software, SDKs, and APIs
      • How Do You Pronounce Saleae?
      • How to Create Project Content for Saleae
  • Returns & Warranty
    • Submit a Warranty Claim
  • Community
    • Ideas & Feedback
    • User Forum
    • Community Projects
    • Community Created Accessories
    • Community Shared Analyzers
  • Tutorials
    • Oscilloscope Tutorial
    • Logic Analyzer Tutorial
    • Learning Portal
      • Digital Protocols
        • Learn Asynchronous Serial
        • Learn I2C - Inter-Integrated Circuit
        • Learn SPI - Serial Peripheral Interface
        • Learn CAN – Controller Area Network
        • Digital MultipleX (DMX512)
        • Manchester
        • 1-Wire
        • Learn I2S / PCM
        • Management Data Input/Output (MDIO)
        • BiSS C
        • HDMI Consumer Electronics Control (CEC)
        • PS/2 Keyboard/Mouse
        • Universal Serial Bus (USB) 2.0
        • Single-Wire Interface (SWI)
        • Simple Parallel
        • Local Interconnect Network (LIN)
        • Joint Test Action Group (JTAG)
      • Common Acronyms and Definitions
      • What is a Glitch?
      • What is RAM? Why Does Logic Use it?
      • What is a Display Radix?
      • What is Data Bandwidth? Can I Reduce this in Logic?
    • Example Projects
      • STM32 Nucleo Board - Digital Signals
      • STM32 Nucleo Board - Analog Signals
      • STM32 Nucleo Board - Analyzing UART
      • STM32 Nucleo Board - Analyzing SPI
      • STM32 Nucleo Board - Analyzing I2C
Powered by GitBook
On this page
Edit on GitHub
Export as PDF
  1. Troubleshooting

Logic Interferes with My Circuit Operation

PreviousWhy Am I Seeing Spikes in the Digital Capture?NextThe Add Analyzer Menu Is Not Displaying

Last updated 3 years ago

All test equipment will have some effect on the signal that it's recording. This effect is usually referred to as loading.

In addition to probe loading, certain types of device failure or partial device failure can cause significantly higher than normal loading. This type of failure is usually limited to only one channel on the device and is covered under the Saleae 3-year warranty.

Capacitive and resistive loading

The effect of an electrical probe on a circuit is usually measured by its equivalent shunt capacitance and resistance. All four of the new products have a capacitive loading of 10 pF and a resistive loading between 1 and 2 Meg Ohms.

This loading is small enough to avoid issues on most signals within the bandwidth of the analyzer (up to 100 MHz digital bandwidth, 5 MHz analog bandwidth). However, these could pose a problem when recording high output impedance signals. It will also cause impedance discontinuities in the signal being recorded.

If you are recording an open drain bus or another bus topology other than CMOS or TTL, then check to see if the bus or IO specification is tolerant of extra pull-down resistance or bus capacitance.

Checking for Issues

If you notice negative effects on your application when a logic analyzer is applied, first check for ground loops. If the problem is caused by a common mode ground voltage, then the issue will appear the moment a ground pin from Logic is attached to your circuit and not when an input probe is connected. The issue will also only be present when the logic analyzer is attached to the host PC and when the device under test is powered. For more information on ground loops, see this article below.

In the absence of a ground loop problem, there could be a problem with one or a few of the inputs on the device. Try using different input channels on the logic analyzer. Also try measuring the resistance between the input pin and the ground pin on the logic analyzer using a multi-meter. If you see a lower resistance than specified for that device, let us know, and we can replace it under warranty.

Please also perform the basic channel functional test described in this article.

Original Logic Input States

The original Saleae Logic (8 channel, digital only) has different input loading when it is not connected to the PC and configured. This loading is significant enough to interrupt some types of signals, including open-drain signals such as I2C.

When using the original Logic, it is recommended to not connect Logic to your device under test until the Logic unit is connected to the PC and the software is running. It is also recommended to disconnect Logic from the device under test before disconnecting it from the PC.

The easiest way to connect and disconnect Logic from your device under test is to simply connect and disconnect the 1x9 wire harness from the unit.

The other Saleae devices do not have significantly different loading when unpowered.

The original Logic is also the only Saleae device to use pulled up inputs. All other Saleae devices have inputs that are pulled to ground. This could cause issues with a circuit that relies on very weak pull-down resistors or when the circuit needs to correctly detect a high-Z state. In these cases, modifications to the circuit may be required. For instance, an extra pull-down resistor could be added to counteract the original Logic's pull-ups.

More information on the inputs of the original Logic can be found below.

Still Unable to Identify the Problem

If the device does not seem to have a problem, there is no ground loop or no common mode ground voltage, but the device is still causing problems with your circuit, please let us know. Also let us know what signals you are recording and what components are connected to that signal. You may want to try recording the signal in analog if you have a Saleae device that supports analog recording or easy access to an oscilloscope. Any information you can submit to support will help.

Safety & Warranty
The Captured Data Looks Incorrect
Supported Voltages